What is the cause of red five ring air compressor flameout?

作者: Bolet air compressor 时间:2024.04.26 Number of page views: 498

Recently, the customer service feedback said that it received the user's reactionRed five ring air compressor flameoutMost of the situation, so the red five ring screw air compressor Xiaobian will introduce in detail to you in this article what are the reasons for the red five ring air compressor flame out:

1. Insufficient air pressure

Air pressure is one of the important conditions for the normal operation of air compressors。If the air pressure is insufficient, the air compressor can not produce enough compressed air, resulting in the red five ring air compressor flameout phenomenon。This condition may be caused by a blocked air inlet, failure of a pressure regulating valve, or failure of a pressure gauge。

2. Motor failure

Motor is the power source to drive the air compressor, if the motor failure, such as winding break, bearing wear, etc., may lead to red five ring air compressor flame out。At this time, it is necessary to check the motor in time and eliminate the fault in order to restore the normal operation of the air compressor。

3. The oil and gas separator is blocked

The oil and gas separator is an important part of the air compressor, which is responsible for separating lubricating oil and impurities in the air。If the oil and gas separator is blocked, the oil content in the compressed air will be too high, which will cause the red five ring air compressor to stall。At this time, it is necessary to clean the oil and gas separator and keep it unimpeded。

4, cooling water system failure

The cooling water system of the air compressor is very important to ensure the normal operation of the air compressor。If the cooling water system fails, such as insufficient water supply, radiator blockage, etc., it may cause the air compressor to overheat, and then lead to the red five ring air compressor flame out phenomenon。At this time, the cooling water system needs to be checked and maintained to ensure its normal operation。

5. Electrical system failure

The electric system of air compressor includes power line, control panel and other components。If there is a fault in the electrical system, such as poor contact of the power cord, failure of the control panel, etc., it may cause the air compressor to stall。At this time, the electrical system needs to be checked and maintained, and the air compressor can be restored to normal operation after troubleshooting。

In short, there may be many reasons for the flameout of the red five ring air compressor, which need us to investigate and deal with from many aspects。If your air compressor also has the above fault phenomenon, you can contact 400-061-9902 consult!